The depth can be 54 min.
Ada door pull clearance.
All doors in alcoves shall comply with the clearances for front approaches.
A pull that has 10 bottom clearance on the outside of the office is now being used as well this is our interchangeable design.
Maneuvering clearances at doors.
Handles pulls panic bars.
On the pull side of hinge approaches 36 min.
All doors in alcoves shall comply with the clearances for front approaches.
Maneuvering clearances at doors.
Elevator car and hoistway doors and gates shall be power operated and shall comply with ansi bhma a156 19 1997 or 2002 edition incorporated by reference see.
60 inches 1525 mm 36 inches 915 mm from hinge side.
60 inches 1525 mm 18 inches 455 mm from front.
On the parallel side beyond the latch is 24 inches should the door need to swing open.
Doors shall not be required to comply with the maneuvering clearance requirements in 404 2 4 1 for approaches to the push side of swinging doors.
Parallel to doorway beyond latch side unless noted from front.
See image below ada accessible compliant pulls projects.
If you approach a door from the latch side and will need to pull the door open the minimum clearance on the opening side perpendicular to the doorway is 48 inches to allow for the door to open leaving room for a disabled individual to move.
Door or gate side.
The ada home page provides access to americans with disabilities act ada regulations for businesses and state and local governments technical assistance materials ada standards for accessible design links to federal agencies with ada responsibilities and information updates on new ada requirements streaming video information about department of justice ada settlement agreements.
Door hardware ada compliant locks exit devices handles pulls latches and other operable parts on doors shall comply operable parts of such hardware shall be 34 inches minimum and 48 inches maximum above the finish floor or ground.
Space at least 60 deep in front of a door will accommodate a forward approach except in case of hinge approaches on the pull side.
404 2 4 1 swinging doors and gates swinging doors and gates shall have maneuvering clearances complying with table 404 2 4 1.
Depending on the direction of approach diagrams a through f illustrate minimum maneuvering space depths and latch side clearances for both push and pull sides of swinging sliding and folding doors.
Depending on the direction of approach diagrams a through f illustrate minimum maneuvering space depths and latch side clearances for both push and pull sides of swinging sliding and folding.
Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door.
48 inches 1220 mm 0 inches 0 mm 1.
Maneuvering clearances at doors.