Grab bars must be installed between 34 and 38 inches above the floor and there must be a separation between the grab bar and the wall surface of at least 1 1 2 inches.
Ada guideline from floor.
Interior and exterior accessible routes including walking surfaces ramps elevators and lifts.
The department of justice s revised regulations for titles ii and iii of the americans with disabilities act of 1990 ada were published in the federal register on september 15 2010.
The bar must be 1 1 4 to 1 1 2 inches in diameter.
These regulations adopted revised enforceable accessibility standards called the 2010 ada standards for accessible design 2010 standards on march 15 2012 compliance with the 2010 standards was required.
This guide explains requirements in the ada standards for floor and ground surfaces.
Door and gate controls must be compliant as operable parts operable with one hand and without tight grasping pinching twisting of the wrist or more than 5 lbf.
Standard roll in shower compartment with folding seat.
4 5 ground and floor surfaces.
Grab bars shall be installed in a horizontal position 33 inches 840 mm minimum and 36 inches 915 mm maximum above the finish floor measured to the top of the gripping surface except that at water closets for children s use complying with 604 9 grab bars shall be installed in a horizontal position 18 inches 455 mm minimum and 27 inches 685 mm maximum above the finish floor measured to the top of the gripping surface.
202 272 0080 or 800 872 2253.
Or for answers to.
202 272 0082 or 800 993 2822.
Where floor drains are provided in bathing rooms it is important that the slope of the floor not exceed the 1 48 minimum cross slope.
Shower floors can slope to drains a 1 48 maximum slope will help control water without impacting accessibility.
4 5 1 general ground and floor surfaces along accessible routes and in accessible rooms and spaces including floors walks ramps stairs and curb ramps shall be stable firm slip resistant and shall comply with 4 5.
Specific questions call the toll free ada information line at 800 514 0301 voice or 800 514 0383.
Clear floor space at door control must be located outside door swing.
Specifications for floor and ground surfaces address surface characteristics carpeting openings and changes in level.
Titles ii and iii of the americans with disabilities act of 1990 ada in the federal register on september 15 2010 which include the 2010 standards for accessible design 2010 standards or standards.
An ada compliant grab bar handrail must be fully anchored and have a smooth surface that can be easily grabbed.
For information about the ada including the revised 2010 ada regulations please visit the department s website www ada gov.
Access board 1331 f street nw suite 1000 washington dc 20004 1111.