Both transfer showers which are not large enough for a wheelchair and roll in showers which are are required to have horizontal bars on two walls at least.
Ada shower vertical grab bar requirements.
Urinal min.
Grab bars shall be installed in a horizontal position 33 inches 840 mm minimum and 36 inches 915 mm maximum above the finish floor measured to the top of the gripping surface except that at water closets for children s use complying with 604 9 grab bars shall be installed in a horizontal position 18 inches 455 mm minimum and 27 inches 685 mm maximum above the finish floor measured to the top of the gripping surface.
Towel sanitary napkins and waste receptacles max.
Toilets need to have horizontal bars behind and next to them and a vertical bar in front.
A vertical grab bar 18 455 mm minimum in length mounted along the side wall.
Grab bars 1 1 4 o 1 1 2 o mounted at 33 above floor with 1 1 2 wall clearance.
Ansi requires 18 455 mm minimum vertical grab bars in addition to the horizontal bars required in accessible toilet or shower stalls.
Requirements for vertical grab bars in toilet rooms.
Each grab bar shall be installed 15 inches 380 mm maximum from the head end wall and 12 inches 305 mm maximum from the control end wall.
Two grab bars shall be installed on the back wall one located in accordance with 609 4 and the other located 8 inches 205 mm minimum and 10 inches 255 mm maximum above the rim of the bathtub.
The showerhead wall must also have a vertical bar on a transfer type shower.
Center line of the bar located 39 990 mm minimum and 41 1040 mm maximum.
Showers ada compliance for showers requires a hand held shower head with 59 1500 mm hose that can be used both as a fixed position shower head and as a hand held shower.
Grab bar code requirements are included in the standard ansii icc a117 1 of the international code council.
14 from wall and 17 above floor with operable control at max.
Shower controls must require less.
44 above the floor.
The ada standards do not require a vertical grab bar at bathing fixtures.
Ada accessible bathrooms for kids should have grab bars at heights of 18 27 inches depending on the primary age group using the bathroom.
The icc a117 1 standard which is referenced by the international building code requires an 18 minimum vertical grab bar at transfer showers and bathtubs.
An l shaped grab bar or two single grab bars with the ends close together shall be provided located along the full depth of the control wall opposite the seat and halfway 18 inches 455 mm along the back wall.
Figure 37 a 36 in by 36 inches 915 mm by 915 mm transfer stall.
A summary of these requirements is below.
The l shaped shower seat shall be 18 inches 455 mm above the floor measured at the entry.
Ada requirements for grab bars in a shower stalls.
Bottom of the bar located 39 990 mm minimum and 41 1040 mm maximum above the floor.