According to the nkba a wall mounted toilet paper holder works best if installed 26 inches above the floor on center.
Ada toilet paper dispenser location.
3 9 out of 5 stars 49.
Toilet grab gars.
On center means that the center of the holder as opposed to the bottom or.
The outlet of the dispenser shall be 14 inches 355 mm minimum and 19 inches 485 mm maximum above the finish floor.
The ada emphasizes grab bar installation because they help the individual maintain balance transfer and prevent falls.
Example of compliant heights to highest operable parts.
If the grab bar is 36 high a non recessed toilet paper dispenser located above the bar must have an outlet at exactly 48 high to accommodate both the max.
Compliant ada dispenser heights and locations.
Bradley offers grab bars in various lengths styles and finishes to fit any application.
If toilet paper dispensers are installed above the side wall grab bar the outlet of the toilet paper dispenser must be 48 inches 1220 mm maximum above the finish floor and the top of the gripping surface of the grab bar must be 33 inches 840 mm minimum and 36 inches 915 mm maximum above the finish floor.
Hand dryer of paper towel dispenser 3.
This document is to be.
Clearance above the grab bar.
17 32 of 421 results for ada toilet paper dispenser kimberly clark bath tissue dispensers.
If toilet paper dispensers are installed above the side wall grab bar the outlet of the toilet paper dispenser must be 48 inches 1220 mm maximum above the finish floor and the top of the gripping surface of the grab bar must be 33 inches 840 mm minimum and 36 inches 915 mm maximum above the finish floor.
The dispenser s outlet shall be between 15 and 48 above the floor and not be located behind the side grab bar or in a position that would obstruct their operation.
Feminine napkin disposal 7.
Toilet paper dispensers shall comply with 309 4 and shall be 7 inches 180 mm minimum and 9 inches 230 mm maximum in front of the water closet measured to the centerline of the dispenser.
Reach height and the 12 min.
Toilet paper dispenser 8.
Section 604 7 of the 2010 ada standards specify that the outlet of a toilet paper dispenser must be within a range of 15 inches to 48 inches above the finished floor.
Toilet tissue dispensers to comply with ada toilet tissue dispensers cannot control delivery or limit paper flow.
Access to the grab bars is an important feature to take into consideration when installing a toilet paper dispenser.
Diaper changing stations 5.
Toilet paper dispensers toilet paper dispensers should be mounted so that the center line is between 7 and 9 in front of the toilet.