Standard toilet stalls are 36 wide by 60 depth.
Ada toilet stall door width.
Toilet partitions and the americans with disabilities act ada restroom partitions are classified as either a standard stall or an alternative stall.
Figure 30 a standard stall.
Multiple toilet stall layouts.
A visual representation of these two can be found easily by reviewing figure 30 a for standard stalls and figure 30 b for alternative stalls.
An example of a single ada bathroom layout.
Doorways shall have a minimum clear opening of 32 in 815 mm with the door open 90 degrees measured between the face of the door and the opposite stop.
The location of the door is in front of the clear space and diagonal to the water closet with a maximum stile width of 4 inches 100 mm.
If there are at least 6 stalls at least one must be further outfitted with parallel grab bars on each side and an outward swinging self closing door.
Figure 30 a standard stall.
Partition stalls can have a minimum depth of 48 in most cases or up to 78 depth if needed.
The minimum width of the stall is 60 inches 1525 mm.
In this stall the centerline of the toilet must be exactly 18 inches from the side of the toilet to the wall and with clear space more than 32 inches to the wall.
Where toilet rooms are provided in multi story facilities that are exempt from the requirement for vertical access between stories 206 2 3 ex.
You want to make sure you are measuring exactly where the partitions will be placed because bathrooms are not always exactly square.
These common pitfalls can spell trouble for ada compliance not just in restrooms but in the rest of your facility.
Clear width is 32 inches 815 mm minimum measured from the face of the door open 90 degrees to the face of the doorstop.
Door closers often require more than 5 pounds of force to open and the last thing you need if you re in a hurry to get there is to be hindered by a door that s too heavy to open ada compliance misconceptions.
The standards specify the location of toilet rooms in two instances.
1 or 2 a toilet room must be provided on a story that is connected to an accessible entrance by an accessible route 213 1.
In a corner handicap stalls require a minimum of 60 x 60 compartment and is required with a minimum door size of 32 and the maximum size and more common is the 36 door.
If toilet stall approach is from the latch side of the stall door clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in 1065 mm.