Adding attic vents is a simple matter of cutting holes and installing vents.
Adding vent to sealed attic.
Obviously it s a bit more complex than that but not much.
First the fumes and chemicals which are connected with keeping a car or using power tools means that you need to draw these away from the rest of the house and second heat build up in an attached garage will also make the house.
By removing the old insulation you ll expose the ceiling.
Space the holes 12 to 14 in.
Screw holes through both flanges.
Next lay the strip vent down on a flat wood surface such as a plywood sheet or long 2 x 4 and drill 1 8 in dia.
When you re done sealing your attic bypasses push the insulation back into place with an old broom handle or stick as you back out of the attic.
Position and fasten the vents.
Protect yourself as you install your insulation.
Photos 1 6 show how it s done.
Apply self adhesive foam weatherstrip tape to the top edge of the stop.
With the help of an assistant raise the vent up to the soffit and center it over the cutout slot.
Though it s against building code to vent any kind of exhaust to an attic space many home builders have gotten away with this shortcut.
Intake vents located at the lowest part of the roof under the eaves allow cool air to enter the attic.
Hot air exhaust vents located at the peak of the roof allow hot air to escape.
But before you cut any holes plan the locations of the attic vents.
However if your attic has blocked soffit vents and is not well sealed from the rest of the house attic fans will suck cool conditioned air up out of the house and into the attic.
Direct all exhaust fans and vents to the exterior.
When you have built an attached garage you will need to think about adding some ventilation to the area ventilating garages properly is vital for two reasons.
If you ve got a vented attic that gets hot in the summer your first option is leave the attic vented and make sure the ceiling is air sealed and insulated as well as possible.
If you ve got an older home and it needs more insulation you ve got the perfect opportunity.
Correct that mistake so that humid exhaust air doesn t get trapped in your insulation and ruin it.
Mark the roof venting locations from the attic where you can see the rafters and avoid placing roofing vents over them.
Attic fans are intended to cool hot attics by drawing in cooler outside air from attic vents soffit and gable and pushing hot air to the outside.
Attic ventilation is usually pretty simple.
Sealed attic construction by excluding vents to the exterior can be a good way to exclude moisture laden outside air from attics and may offer a more easily constructed alternative for air leakage control at the top of residential buildings.